Tender Details
Design and construction for the upgrading of the existing fire safety systems to the following sites:
1. Turanga 1 Phillip Street, Waterloo
2. Matavai 3 Phillip Street, Waterloo
3. Cook 200 Pitt Street, Waterloo
4. Banks 249 George Street, Waterloo
5. Marton 149 Ceope Street, Waterloo
6. Solander 180 Pitt Street, Waterloo
Fire safety systems to be designed, constructed and upgraded include:
· Fire sprinklers
· Compartmentation
· Fire detection and emergency warning systems
· Emergency lighting and exit signage
· Fire hydrants and hose reels
· Exiting fire door sets
· Life safety signage
· Access and egress
FIRE SPRINKLERS
Buildings may or may not contain a sprinkler system. Where sprinklers have been installed, they must be upgraded or replaced to meet compliance to AS2118.1
Compartmentation Upgrade
Intermediate floors and bounding walls separating Sole Occupancy Units (SOU’s) are required to contain a fire resistance level of not less than 90/90/90 to AS1540.4, AS1530.1, AS1668.1, AS1682.1, Specification C1.1 Part 3.1 of BCA 96, Clause 3.2 of BCA 96, Clause 3.11 of BCA 96.
The integrity of the floor slabs and bounding walls need to be maintained. It is therefore required that any penetration through the floor slab or bounding wall be upgraded to achieve a level of integrity and insulation of not less then -/90/90.
Roofs and or ceilings are required to contain a fire resistance level of not less than 90/60/30 to AS1540.4, AS1530.1, AS1668.1, AS1682.1, Specification C1.1 Part 3.1 of BCA 96.
Any bounding wall is required to have an FRL of 90/60/30 with respect to integrity or insulation to extend to either a roof with an FRL of 90/60/30 or a ceiling that is immediately below the roof and has a resistance to the incipient spread of fire to the roof space between the ceiling and the roof of not less than 60 minutes.
The integrity of the ceilings needs to be maintained. It is therefore required that any riser extending into the roof space and any penetration through the ceiling be upgraded to achieve a level of integrity and insulation of not less then -/90/90 and -/60/60 respectively.
Fire Detection and Emergency Warning Systems
Buildings may or may not contain a fire detection and emergency warning system. Where these systems have been installed, they must be upgraded / replaced to meet compliance to AS1670.1.
Emergency Lighting and Exit Signage
Buildings contain an emergency lighting and exit signage system. Where these systems have been installed, they must be upgraded / replaced to meet compliance to AS2293.1, BCA Part E4.
Fire Hydrants and Hose Reels
Buildings contain a fire hydrant system. Where these systems have been installed, they must be upgraded / replaced to meet compliance to AS2419.1
Exiting Fire Doors Sets
The integrity of the fire doors needs to be maintained. It is therefore required that any non compliant plant rooms or fire isolated exit fire doors be upgraded to achieve a level of integrity and insulation of not less then -/120/30 and -/60/30 respectively.
Doorways to rooms/spaces that are separated from the building with 120/120/120 fire rated construction eg lift motor rooms, boilers, switch rooms, etc are required to be protected with a -120/30 fire door set to Part 3.4 of BCA and Part 3.8 of BCA, Performance Requirements of Section C of BCA.
Doorways to all fire isolated exits eg fire stairs, fire isolated passages, etc are required to be protected with a -60/30 fire door set to Part 2.12 of BCA and Part 2.13 of BCA, Performance Requirements of Section C of BCA.
Life Safety Signage
The life safety signage has been upgraded on a progressive maintenance basis and no additional upgrade work other than that mentioned within this specification has been identified as required.
4.8 Access and Egress
Services or equipment must not be installed in a required exit or in any corridor, hallway, lobby or the like, leading to a required exit if it comprises of electricity meters, central telecommunications distribution boards or equipment, electrical motors, etc unless it is enclosed by a non combustible construction or a fire protective covering with doorways or openings suitably sealed against smoke spreading from the enclose to Clause D2.7 of BCA 96.
The invited firms are listed below
Location
RFT Type
Tender Respondents
Business Name | Trading Name | Address |
---|---|---|
Automatic Fire Protection Design Pty Ltd | Blaze, Blazemaster, Country Fire and Safety, Rhino Fire Protection, Automatic Fire Protection | 20 Binney Road Kings Park NSW 2148 AUSTRALIA |
CBC Facilities Maintenance Pty Ltd | Paul's Building Consultants | 104 Auburn Street Wollongong NSW 2500 AUSTRALIA |
Firecorp Australia Pty Limited | - | Unit 3, 27 Holden Street Ashfield NSW 2131 AUSTRALIA |
Tyco Australia Pty Limited | Wormald Fire Systems | 1/2-8 South Street Rydalmere NSW 2116 AUSTRALIA |
Additional Details / Instructions
Mandatory site tender meeting:
· Date: 11/09/09
· Time: 1100h
Venue: Matavia - 3 Phillip Street, Waterloo
NOTES TO INVITED FIRMS
To access the RFT files and to lodge a response you must use the Access PassCode provided to you by the contact officer.
Obtaining the RFT Documents
Click on the DOWNLAOD A SOFT COPY - Free link at the bottom of the page, use the Access Passcode provided to gain access, then register your firm in the system (if not previously registered), and follow onscreen instructions to download the RFT document files provided.
Lodging a Response
Your completed tender should be lodged as allowed in the RFT Document, however, it may also be lodged electronically via this web page.
As the tenderer you must be a current Registered user of this web site.
Click on the blue LODGE ON RESPONSE link at the bottom of this page, using the Access Passcode, then using your registered system Username / Password and follow the on-screen instructions to be taken to the lodging screen to submit your electronic tender response.
Software Requirements
To be able to view the requirements within the RFT you will require the following software to be installed on your PC:
Adobe Acrobat Reader to be taken to their free download site now.
Winzip to be taken to their free evaluation download site now.
The RFT also requires the following software:
· Microsoft - Word 2003 (or more recent) or equivalent
· Microsoft – Excel 2003
Other requirements:
* Internet connection to lodge completed tender response.
The tenderer is responsible for the provision and installation of the necessary software.
Conditions for Participation
Access to this RFT is restricted to invited firms only. The invited firms are:
Those Firms (Listed Below) have been issued with the special Access Pass-code required by this RFT.
* Tyco Fire & Security T/A Wormald. Unit 1, 2-8 South Street, Rydalmere NSW 2116 .
* Firecorp Australia P/L, 27 Holden Street. Ashfield, NSW 2131
* CBC Facilities Maintenance P/L. 104 Auburn Street. Wollongong NSW 2500
* Triple “M” Fire P/L. Quad 4, Level 1, 8 Parkview Drive, Homebush Bay NSW 2127.
Tender will only be accepted from the invited firms listed