TransGrid / Vineyard 330/132 kV Substation New 330 kV Transformer Compound & Associated Civil & Electrical Works - 1303

RFT ID 1303
RFT Type Open Tenders
Published 25-May-2010
Closes 22-Jun-2010 11:00am
Category Electrical power transmission engineering
Agency TransGrid


Contact Person
Chris Jones
Phone: 02 9620 0268
chris.b.jones@transgrid.com.au

Tender Details

The Principal’s Vineyard substation is located in Western Sydney, NSW and supplies power to Integral Energy’s zone substations in the area.  To accommodate growing load in the area, the substation is to be augmented by the provision of an additional 330/132 kV transformer unit and associated switchbays.  The Principal will supply the transformer and HV plant. The Contractor will be responsible for all Civil and Electrical works, including high and low voltage connections and carrying out pre-commissioning tests.

 

The augmentation works include the following:

 

  • Extension of the existing switchyard bench,
  • Construction of one new transformer compound,
  • Installation of one new 330/132kV transformer and auxiliary transformer,
  • Construction of two associated 330kV and 132kV transformer switchbays,
  • Connection of transformer compound into existing site spill oil containment system.
  • Upgrading and enlarging the secondary oil containment dam and outlet connections.

Location

NSW Regions: Sydney

RFT Type

Open Tenders - An invitation to tender by public advertisement with no restriction placed on who may tender. Tenderers will normally be required to demonstrate in their tender that they have the necessary skills, resources, experience, financial capacity, and in some cases licences, accreditations, etc., to fulfil the tender requirements.

Additional Details / Instructions

MANDATORY INSPECTION OF SITE

A mandatory site inspection will be held on 1st June 2010 commencing at 10.30am at the existing Vineyard 330kV switchyard which is located on Bandon Drive, Vineyard NSW. Further information on the site inspection can be obtained by telephoning the technical contact.

All participants must register for the mandatory site inspection. All participants are to register via the technical contact.

All personnel attending the site inspection must wear long sleeve shirts, trousers, safety helmets, enclosed footwear, and high visibility shirts or vests when entering switchyards, along transmission line sites or in any other area where a safety helmet is required.